Connect AI assistants to your PLCs, meters and OPC UA servers

Proxus Industrial MCP Server gives Claude, Cursor, VS Code and any other MCP client read-only access to the devices you list: Modbus TCP and OPC UA, with OPC UA security and certificates. 60+ open register maps are built in, so the assistant reads a meter's voltage by name instead of guessing addresses. Ask what a machine is doing, why a value looks wrong or why a device does not answer, and it reads the plant to find out.

  • Windows, macOS, Linux and Docker
  • One binary, no runtime to install
  • Read-only by design
  • Listed in the official MCP Registry
AI assistant · MCP Product UI · sample data
Map: eastron/sdm630-modbusRead-only

MCP · read_named reading… ✓ 4 values · 38 ms
read_named(device: "sdm630-1", keys: ["voltage_l1_n", "current_l1", "frequency", "active_power_l1"])
voltage_l1_n 230.4 V
current_l1 12.6 A
frequency 50.00 Hz
active_power_l1 8,420 W

An AI assistant uses the Proxus MCP server to read a PLC, decode a meter value, watch a voltage and diagnose a device that does not answer.
A real session against simulated devices: the assistant picks the tools on its own.

Tools

What the assistant can do

Each tool answers a question engineers ask on the floor. Results come back with units, quality and timestamps, so the assistant can say how sure it is.

list_devices
The devices this server may reach, with their ISA-95 path and whether a connection is open.
read_nodes · browse
Browse an OPC UA server and read up to 50 variables with quality, status code and source timestamp.
read_address · decode_registers
Read Modbus registers and bits, and show every byte and word order side by side when a value looks wrong.
watch_nodes · watch_address
Watch values for up to a minute: an OPC UA subscription or Modbus polling, with min, max, average and every change.
diagnose_connection
Walk name, TCP, protocol, certificates, login and a test read, and name the layer that fails with the next thing to try.
find_device_map · get_device_map
Find the register map for a model or alias such as PM5560, and look up its registers by word: address, type, byte order, unit and scale.
read_named
Read registers by key, such as voltage_l1_n or active_energy_import, and get engineering values with units; the map supplies type, byte order and scale.
verify_device_map
Check a map against the real device, read-only, and prepare a hardware verification report for the open collection.

Setup

Running in five minutes

  1. Download Get the archive for Windows, macOS or Linux from the releases page, or use the Docker image.
  2. List your devices Write the devices the assistant may reach in proxus-mcp.json, with a register map for Modbus devices that have one. Nothing outside that file is reachable.
  3. Add it to your MCP client Point Claude Desktop, Cursor or VS Code at the binary and the configuration file, then restart the client.

proxus-mcp.json

{
  "devices": {
    "energy-meter-1": {
      "protocol": "modbus-tcp",
      "host": "192.168.10.40",
      "unit_id": 1,
      "map": "schneider-electric/pm5500-pm5600-pm5700"
    },
    "press-3": {
      "protocol": "opc-ua",
      "endpoint": "opc.tcp://192.168.10.21:4840",
      "security_mode": "sign_and_encrypt",
      "security_policy": "Basic256Sha256"
    }
  }
}

Claude Desktop: claude_desktop_config.json

{
  "mcpServers": {
    "proxus": {
      "command": "/path/to/proxus-mcp",
      "args": ["--config", "/path/to/proxus-mcp.json"]
    }
  }
}

Register maps built in

Read meters and drives by name

The server ships with the open Modbus Register Maps collection: 60+ energy meters, power analysers, drives and inverters, 20,545 registers, each with its vendor document. Set a device's map in the configuration and the assistant calls read_named instead of decoding raw registers.

Browse all register maps

Verify a map on your device: verify_device_map reads every register once, checks the values and prepares a report you submit to the collection.

Built for the plant floor

Safe to point at production

  • Read-only: no tool writes values, starts or stops a machine, or changes a controller. Register maps say how to read a register, never how to write one.
  • Only the devices in the configuration file are reachable; the assistant cannot scan the network.
  • OPC UA Basic256Sha256, Aes128_Sha256_RsaOaep and Aes256_Sha256_RsaPss with Sign or SignAndEncrypt; certificates are never trusted automatically.
  • Passwords come from environment variables, never from the configuration file.
  • Text read from devices is returned as data, so a tag value cannot steer the assistant.

From one engineer to the whole plant

When one MCP server is not enough

The MCP server talks to devices one session at a time. Proxus runs the same idea across the plant: every signal collected once, history kept, a Unified Namespace for all sites, Siemens S7, EtherNet/IP, CNC and more protocols, and the AI Assistant and MCP access with users, roles and an audit trail.

  • History and trends, not only what a device reports now.
  • More protocols: Siemens S7, EtherNet/IP, Fanuc, Heidenhain and others.
  • Users, roles and an audit trail for every AI request.

Questions

MCP server questions, answered.

What is an MCP server?
MCP (Model Context Protocol) is an open standard that lets AI assistants call tools. An MCP server offers those tools; here they read industrial devices. Claude Desktop, Cursor, VS Code and other MCP clients start the server and let the model decide when to call each tool.
Can the assistant change values on my PLC?
No. Every tool in this release only reads. There is no tool that writes a value, starts or stops a machine, or changes a controller program, and only the devices in the configuration file can be reached.
Which protocols does it support?
Modbus TCP and OPC UA. Modbus RTU devices are reached through a Modbus TCP gateway. OPC UA works unsecured or with Basic256Sha256, Aes128_Sha256_RsaOaep and Aes256_Sha256_RsaPss, Sign or SignAndEncrypt, with anonymous or user-name login. Siemens S7, EtherNet/IP and CNC controls are available in the Proxus platform.
Which devices have a register map?
Energy meters, power analysers, variable speed drives and solar inverters from ABB, Eastron, Fronius, Schneider Electric and Siemens: 60+ maps today, listed on the register maps page. Other Modbus devices work with read_address and decode_registers, and maps are added through the open collection on GitHub.
Does it work without the cloud?
Yes. The server runs on your machine and talks to the devices directly. Your AI client decides where the conversation is processed; the device data goes only to the client that started the server.
Is it free?
Yes. It is open source under the Apache-2.0 licence, including for commercial use. The protocol drivers it uses are published as open-source NuGet packages too.