Open Modbus register maps
Every register of a device in one table: the address on the wire, the 30001-style reference, data type, byte order, unit and scale, with the vendor document it comes from. 15+ devices and 12,661 registers so far, free to use in any project.
- devices
- 15+ devices
- registers
- 12,661 registers
- verified on hardware
- 0 verified on hardware
Energy meters
- ABB B23/B24 121 registers ABB B23 · ABB B24 · B23 112-100 · B23 312-100 Not yet verified on hardware
- Eastron SDM120-Modbus 32 registers SDM120 · SDM120M · SDM120Modbus Not yet verified on hardware
- Eastron SDM630-Modbus 97 registers SDM630 · SDM630 V2 · SDM630Modbus Not yet verified on hardware
- Fronius Smart Meter 73 registers Fronius Smart Meter TS · Fronius Smart Meter IP Not yet verified on hardware
Power analysers
- Schneider Electric PM5100/PM5300 877 registers PowerLogic PM5100 · PowerLogic PM5300 · PM5110 · PM5111 Not yet verified on hardware
- Schneider Electric PM5500/PM5600/PM5700 3,108 registers PowerLogic PM5500 · PowerLogic PM5600 · PowerLogic PM5700 · PM5560 Not yet verified on hardware
- Siemens PAC3200 151 registers SENTRON PAC3200 · 7KM2112-0BA00-3AA0 · 7KM2111-1BA00-3AA0 Not yet verified on hardware
- Siemens PAC4200 222 registers SENTRON PAC4200 · 7KM4212-0BA00-3AA0 · 7KM4211-1BA00-3AA0 Not yet verified on hardware
Solar inverters
- Fronius Primo GEN24 Plus/Symo GEN24 Plus 224 registers Primo GEN24 Plus · Symo GEN24 Plus · Fronius GEN24 Plus Not yet verified on hardware
- Fronius Primo GEN24/Symo GEN24 178 registers Primo GEN24 · Symo GEN24 · Fronius GEN24 Not yet verified on hardware
- Fronius Tauro 188 registers Fronius Tauro Not yet verified on hardware
- Fronius Tauro ECO 168 registers Fronius Tauro ECO Not yet verified on hardware
- Fronius Verto 3 MPPT 188 registers Fronius Verto Not yet verified on hardware
- Fronius Verto 4 MPPT 198 registers Fronius Verto Not yet verified on hardware
- Fronius Verto Plus 234 registers Fronius Verto Plus Not yet verified on hardware
Variable speed drives
- Schneider Electric ATV320 1,071 registers Altivar Machine ATV320 · ATV320U · ATV320D Not yet verified on hardware
- Schneider Electric ATV340 1,741 registers Altivar Machine ATV340 · ATV340U · ATV340D Not yet verified on hardware
- Schneider Electric ATV600 1,879 registers Altivar Process ATV600 · ATV610 · ATV630 · ATV650 Not yet verified on hardware
- Schneider Electric ATV900 1,911 registers Altivar Process ATV900 · ATV930 · ATV950 · ATV960 Not yet verified on hardware
No map matches. Ask for the device on GitHub and it goes on the list.
How the maps are made
One address convention, and the source for every value
- Zero-based wire addresses
- Vendor manuals mix 30001, 0x0000 and "register 1". Every map stores the address sent on the wire; the 30001-style reference is derived from it, so the two never disagree.
- Checked against the source
- Maps are transcribed from the vendor document they list, with its version, and every address is checked back against that document by script.
- Typed and scaled
- Each register carries its data type, byte order, unit and scale (fixed, or a SunSpec scale-factor register) and the meaning of enumerated values.
Hardware verification levels
- L1
- The registers answer on a real device.
- L2
- The values pass automatic plausibility checks: floats, frequency, voltage, power factor, energy counters, model.
- L3
- A person compared values with the device’s own display.
A map without a level is transcribed from its sources and not yet read from hardware. Verifying one takes a few minutes with the Proxus MCP server.
Use them
Read a device by register name
The Proxus Industrial MCP Server ships with every map in this collection. Give a Modbus device its map, and an AI assistant reads voltage_l1_n instead of guessing that hr:0-1 is a word-swapped float.
The JSON file is attached to every proxus-mcp release (this page: v0.1.0-beta.7). Each map is also a YAML file in the repository.
Have one of these devices?
A hardware verification is the most useful contribution: read-only, a few minutes, and your name goes on the map’s verified list. Missing a device? Request it with a link to its Modbus document.