Siemens data collection with Proxus
Proxus reads Siemens PLCs with a native driver in the gateway. No PLC program changes, no OPC server in between: configure the device in the hub and the values arrive in your Unified Namespace.
A Proxus engineer replies within one working day.
Protocols and ports
7 protocols in this family.
The port used when you leave Port empty, browsing the device, and finding servers on the network. The connection test works for every protocol.
Before the first read: On S7-1200 and S7-1500, allow PUT/GET communication from remote partner in the CPU settings, and check rack and slot. Troubleshoot devices
Over TCP: a serial protocol carried over TCP, through a serial device server or a converter. Proxus does not open serial (COM) ports directly.
-
Siemens PPI Over TCP
Port when empty: enter it
Browse: No
Discovery: No
-
Siemens S7-200
Port when empty: 102
Browse: No
Discovery: No
-
Siemens S7-300
Port when empty: 102
Browse: No
Discovery: No
-
Siemens S7-400
Port when empty: 102
Browse: No
Discovery: No
-
Siemens S7-1200
Port when empty: 102
Browse: No
Discovery: No
-
Siemens S7-1500
The wizard shows one Siemens S7 card with a switch for the CPU family. The test also reads the CPU's order number.
Port when empty: 102
Browse: No
Discovery: No
-
Siemens S7-200 Smart
Port when empty: 102
Browse: No
Discovery: No
Source: protocol reference
How it works
From the machine to your systems, in four steps.
- 01
Add the device in the hub
Choose the protocol that matches your equipment, enter its address and pick the gateway on the same network.
- 02
Define the tags
Enter the addresses you need or apply a device profile, so the next identical machine is a matter of applying the profile.
- 03
Name it in the namespace
Each value gets its place in the Unified Namespace (enterprise, site, area, line or cell, equipment), the same for every protocol.
- 04
Deliver and act
Send the values to databases, brokers, cloud and APIs, and run rules and anomaly detection at the edge.
Moving from Kepware
Running Kepware today?
Proxus imports channels, devices and tags from a running Kepware server. Siemens, Modbus Ethernet and OPC UA client channels are converted to the matching Proxus protocol; nothing changes on the Kepware side.
-
Runs at the edge
The driver runs inside the gateway on the plant network. Data keeps being read when the link to the hub is down.
-
Buffered through outages
Delivery to the hub and to every outbound target queues at the gateway (48 hours by default, up to 30 days) and is sent in order when the connection returns.
-
Nothing opens inbound
The gateway connects out to the hub (port 7422, over TLS). Nothing on the plant network has to accept connections from the hub.
-
No per-tag pricing
Tags, devices and users are not counted. You license gateways and data rate.
See pricing
Setup details: protocol reference · Add a device · All drivers
Connection guides
Set it up step by step.
- Siemens S7MQTTSiemens S7 to MQTT: read an S7 PLC and publish its values to your brokerConnect an S7-1200, S7-1500 or older S7 CPU and publish its tags to your own broker.Read the guide
- PLCSQL ServerPLC data to SQL Server: write every reading into a table, continuouslyRead any supported PLC and write one row per reading into a SQL Server table.Read the guide
Next step
Send us your equipment list.
List your Siemens models and the other machines on the line. We confirm which protocol each one uses and what it takes to connect it.
- 01
Scoping call
Equipment, protocols, sites and the systems the data has to reach.
- 02
Technical walkthrough
A working demo against a scenario that resembles your plant, not a generic tour.
- 03
Pilot plan
A defined first line or site, with the deployment and security questions answered up front.
- 04
Roll-out
The same templates bring the next lines and sites online.