Protocols
The protocols the edge gateway runs, by vendor, with the default port and which ones support a connection test, browsing and discovery.
This list is the set of protocols the edge gateway runs, the same set the device setup wizard offers. Protocol names appear here as they do in the hub.
What the columns mean
- Port when empty: the port the gateway uses when you leave Port empty. "Enter it" means the protocol has no usual port and the device's port must be typed in.
- Test: the wizard's Test the connection works for every protocol on this page. The gateway connects to the address, opens a protocol session and, if you added tags, reads them once.
- Browse: the protocol can list the device's values for you (From the device in the wizard's tag step).
- Discovery: the wizard can search the network for servers of this protocol (Server discovery).
- Over TCP in a name means a serial protocol carried over TCP, through a serial device server or a converter. Proxus does not open serial (COM) ports directly.
Open standards
| Protocol | Port when empty | Browse | Discovery | Notes |
|---|---|---|---|---|
| OPC UA | from the endpoint URL (opc.tcp://server:4840) | Yes, folder by folder | Yes | Discovery tries opc.tcp 4840 and 53530 and opc.https 53443 ([Browse] OpcUaDiscoveryPorts). Server certificates are trusted in the hub. See OPC UA. |
| Modbus TCP | 502 | No | No | Datasheet numbers such as 40001 are converted for you. |
| Modbus RTU Over TCP | 502 | No | No | |
| Modbus ASCII Over TCP | 502 | No | No | |
| MTConnect | enter it | Yes | Yes | An MTConnect agent over HTTP. Discovery tries ports 5000, 5001, 5005, 5006 and 7000 ([Browse] MtConnectDiscoveryPorts). See MTConnect. |
| SNMP | 161 (UDP) | Yes | No | |
| Simulator | none | No | No | Values generated on the gateway, for trying pipelines, dashboards and rules without a device. See Simulator. |
Siemens
| Protocol | Port when empty | Browse | Discovery | Notes |
|---|---|---|---|---|
| Siemens S7-1500 | 102 | No | No | The wizard shows one Siemens S7 card with a switch for the CPU family. The test also reads the CPU's order number. |
| Siemens S7-1200 | 102 | No | No | |
| Siemens S7-300 | 102 | No | No | |
| Siemens S7-400 | 102 | No | No | |
| Siemens S7-200 Smart | 102 | No | No | |
| Siemens S7-200 | 102 | No | No | |
| Siemens PPI Over TCP | enter it | No | No |
Rockwell Automation
| Protocol | Port when empty | Browse | Discovery | Notes |
|---|---|---|---|---|
| Allen Bradley | 44818 | Yes | No | ControlLogix and CompactLogix (EtherNet/IP, CIP). Browsing lists the controller's tags. |
| Allen Bradley MicroCip | 44818 | No | No | |
| Allen Bradley PCCC | 44818 | No | No | |
| Allen Bradley SLC | 44818 | No | No |
Mitsubishi Electric
| Protocol | Port when empty | Browse | Discovery |
|---|---|---|---|
| Mitsubishi Melsec MC | enter it | No | No |
| Mitsubishi Melsec MC ASCII | enter it | No | No |
| Mitsubishi Melsec MC R | enter it | No | No |
| Mitsubishi Melsec A1E | enter it | No | No |
| Mitsubishi Melsec A1E ASCII | enter it | No | No |
| Mitsubishi Melsec A3C Over TCP | enter it | No | No |
| Mitsubishi Melsec CIP | 44818 | No | No |
| Mitsubishi Melsec FX Links Over TCP | 485 | No | No |
| Mitsubishi Melsec FX Serial Over TCP | enter it | No | No |
Omron
| Protocol | Port when empty | Browse | Discovery |
|---|---|---|---|
| Omron FINS | 9600 | No | No |
| Omron CIP | 44818 | No | No |
| Omron Host Link Over TCP | enter it | No | No |
| Omron Host Link C Mode Over TCP | enter it | No | No |
Other PLC vendors
| Protocol | Port when empty | Browse | Discovery |
|---|---|---|---|
| Beckhoff ADS | enter it: left empty, the gateway uses 851, which is not the ADS TCP port (usually 48898) | No | No |
| Delta TCP | 502 | No | No |
| Delta Serial Over TCP | 502 | No | No |
| Delta Serial ASCII Over TCP | 502 | No | No |
| FATEK Program Over TCP | enter it | No | No |
| Fuji SPH | 18245 | No | No |
| Fuji SPB Over TCP | enter it | No | No |
| GE SRTP | 18245 | No | No |
| Inovance TCP | 502 | No | No |
| Inovance Serial Over TCP | 502 | No | No |
| Keyence MC | enter it | No | No |
| Keyence MC ASCII | enter it | No | No |
| Keyence Nano Serial Over TCP | 8501 | No | No |
| LSIS XGB Fast Ethernet | 2004 | No | No |
| LSIS XGB Cnet Over TCP | 2004 | No | No |
| LSIS XGK Fast Ethernet | 2004 | No | No |
| MegMeet TCP | 502 | No | No |
| MegMeet Serial Over TCP | 502 | No | No |
| Panasonic MC | enter it | No | No |
| Panasonic Mewtocol Over TCP | enter it | No | No |
| Toyo PUC | enter it | No | No |
| Vigor Serial Over TCP | enter it | No | No |
| XINJE TCP | 502 | No | No |
| XINJE Serial Over TCP | 502 | No | No |
| XINJE Internal | 502 | No | No |
| YASKAWA Memobus TCP | 502 | No | No |
| Yokogawa Link TCP | enter it | No | No |
| Freedom TCP | enter it | No | No |
Since 2.0.0, Mitsubishi Melsec A1E ASCII devices use the A1E ASCII protocol (before, they could not connect), and XINJE TCP and XINJE Serial Over TCP each use their own driver (before, the two were swapped). No setting change is needed.
CNC machines
| Protocol | Port when empty | Browse | Discovery |
|---|---|---|---|
| Fanuc Series 0i | 8193 | No | No |
| Haas MDC | 5051 | No | No |
| Heidenhain LSV2 | 19000 | No | No |
MTConnect, in the first table, is the usual way to read other CNC controls through an agent.
Robots and other devices
| Protocol | Port when empty | Browse | Discovery |
|---|---|---|---|
| Fanuc Interface | 60008 | No | No |
| Kuka TCP | 7000 | No | No |
| YASKAWA YRC1000 TCP | 10040 | No | No |
| Estun TCP | 502 | No | No |
| ER7BC10 | 8080 | No | No |
| Turck Reader | enter it | No | No |
Protocols that are not available
These protocols are not part of the gateway in this release, and are not offered when you add a device: IEC 104, DLT 645/698, CJT 188, Atlas Copco Open Protocol, SECS/HSMS, the UDP variants of Modbus, Omron FINS, Melsec MC and Memobus, and MQTT and HTTP as device protocols. If your equipment needs one of them, ask us about it.
To bring in data from a device that speaks MQTT or HTTP, let it publish to the gateway's broker (see MQTT and the UNS topics) or poll it with a function.